3PAR StoreServ 7000 Hardware – Part 3

This is where things start to pick up a bit as we venture onto adding the StoreServ 7000 into the Virtual Service Processor.

Browse to your VSP using the IP Address you configured in 3PAR StoreServ 7000 Hardware – Part 2 and login with your credentials.  A quick side note you may here the term SPOCC banded around quite a bit it stands for ‘Sevice Processor Onstie Customer Care’.  Any how, click on SPMaint

SP 1

Select Inserv Configuration Management

SP 2

Guess what we need to Add A New InServ

SP 3

Enter the IP Address of your StoreServ 7000

SP 4

Verify the details and click ‘Add New InServ’

SP 5

Man Down – Replacing a Failed Hard Drive

A slightly over exaggerated title, but I’m sure it grabbed your attention.

The StoreServ has a feature called ‘Guided Maintenance’ this essentially shows you how to perform a number of tasks e.g. replace a DIMM, Fiber Channel Adapter.  This can be found under Support > Guided Maintenance

SP 6

Perhaps the most common failure you will encounter is replacing a fauly disk.  This can be done via the CLI by SSH onto your StoreServ or via the VSP by going to SPMaint > Execute a CLI Command and entering ‘servicemag status’.

servicemag

As I don’t have a failed disk it shows ‘No servicemag operations logged’

If you did have a failed disk, you will be told which Cage and Magazine has a failure and that the Magazine has been taken offline to allow you to replace the faulty HDD.  Once you have replaced the disk, give it 15 minutes and re issue the servicemag status command and when complete you will see ‘No Servicemag operations logged’.

You can also check via the GUI in the 3pAR Inform Management Console by going to ‘System’ > Physical Disks > and then looking down the cages.

Failed Disk

Double check the HDD if Failed and that Free Capacity and Allocated Capacity is displayed as all zeroes.  If this is the case, then pop the badboy out and pop a new one in.

Man Down – Servicing a Power & Cooling Module (PCM)

This is only available via SSH onto your StoreServ or via the VSP by going to SPMaint > Execute a CLI Command

To confirm if the PCM is down issue the command shownode -ps

As you can see mine are OK, however, if you had a failure then replace the SPM and run the command again until you see both PCM are OK.  Note this can be done live without any downtime.

ShowNode PS

Man Down – Replacing and Power & Cooling Module (PCM) Battery

The Power and Cooling Module Battery is again only available via SSH onto your StoreServ or via the VSP by going to SPMaint > Execute a CLI Command.

The battery is located at the top of the  PCM.

To verify your battery status issue the command showbattery

showbattery

Again if it was failed replace the part and re issue the showbattery command to verify it’s healthy.

Drive Enclosure Expansion

The StoreServ 7200 is limited to five extra drive enclosures.  Two can be connected via DP1 and three can be connected via DP2.

The StoreServ 7400 with two nodes is limited to nine extra drive enclosures.  Four can be connected via DP1 and five can be connected via DP2.  Note these figures double to a four node StoreServ 7400.

You might be thinking why does DP2 have more connections? Well the answer if that DP1 is also responsible for the internal connections, which evens things out.

The procedure to add an additional drive enclosure is:

  1. Rack the Drive Enclosure
  2. Install Power & Cooling Modules
  3. Power On
  4. Install Hard Drives
  5. Run command ‘servicecage startfc’ this will move all I/O to Node 1 (remember Node 0 is the first Node)
  6. Connect the SAS cable, the first connection should be out IFC 0 and in IFC0 on the new Drive Enclosure
  7. Run command ‘servicecage endfc’ and this will restore I/O to Node 0.
  8. Repeat for same procedure for Node 1.
  9. Connect the Drive Enclosure to the Controller Nodes

One of the slightly tricky parts is the disk shelf cabling.  Some rules to follow:

  • Event Nodes go to Even Controllers
  • Odd Nodes go to Odd Controllers
  • Odd Nodes connect to the highest Disk Shelf first
  • Even Nodes connect to the lowest Disk Shelf first

3PAR Disk Shelf Cabling

Run the showcage command to verify you new Disk Enclosure is recognised.

showcage

Disk Upgrade Rules

These are the golden rules which need to be followed.

  1. You need to add the same number of disk drives to the Drive Enclosure as are in the Node Enclosure e.g. if you are using 24 disks in your Node Enclosure you will need to add 24 disks to your rive Enclosure.
  2. When adding disks to a StoreServ 7200 without a Disk Enclosure they should be done in pairs and placed in the lowest slots.  On a 2.5″ Disk Enclosure this is left to right.  On a 3.5″ Disk Enclosure this is per column left to right and top to bottom within the column.
  3. For a StoreServ 74000 without a Disk Enclosure four node system the same rules apply except you have to add four disks at a time.
  4. If you have a StoreServ 7200 with a Disk Enclosure.  You would need to add a minimum of four disks.  Two to the Node Enclosure and two to the Drive Enclosure.

11 thoughts on “3PAR StoreServ 7000 Hardware – Part 3

  1. HI Craig!
    Can you please explain you rules about adding disks to 3PAR? Are there any docs to read about this process?
    Thanks!

      1. Craig, my question was just about your rules. I want to know if there are any official docs where this process was described or how you create your rules. sorry 4 my bad english:(

      2. The information can be found in the HP Learning Center search for HP 3PAR 7000 Array Hardware.

  2. Hi. Can you help me? I can assign IP address to management interface on Hp 3Par Storesrv 7200. How can I do it. ?

  3. HI
    Can you please explain How to add the Drive enclosure to the existing StoreServ 7200?How to do the back end cabling to the new Drive Cage? Should i disturb the existing SAS cabling to re connect to the new enclosure or without removing the existing cables ,simply can we do the daisy chain to the existing drive cage! Are there any docs to read about this process?
    Thanks!

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s